產品介紹
WP400c
- FP-COMB 32
- FP-COMB 63/690-1
- FP-EFT 100M2
- FP-SURGE 100M2
- PCD 121
- PCD 126 A
- PCD 122
- DEC 5
- DEC 6
- DEC 7
Haefely
Coupling / Decoupling Networks (CDN)
Electrostatic Discharge (ESD)
Power Frequency Magnetic Fields
Pulse Magnetic Field Test Systems
Software
水冷機零件
BONN
RF Power Amplifiers
RF Amplifier Modules
EMI Preamplifiers
Directional Couplers (internal and external)
Waveguide-Coax Adapter
RF Power Attenuators
RF Power Terminations
各式CDU
Cooling
- R&S FSL
- AMETEK TESEQ NSG 437
- 音壓放大器
二手儀器專區
Rohde & Schwarz
TESEQ
Brüel & Kjær
- WP10M
- WP50
- WP400
- WP400-3
- WP400c
- WPF3
- WPF6
- WPF8
- WPF18
- WPF40
- WPF60
- WPF60S
- WPF90
- WPH60
- WPH1000
- WPH-DC
- 校正服務 (Calibration Services)
Wavecontrol
Field Probes
Calibrations
NOISEKEN -INS4040/4020水銀繼電器販賣
各式EMC ESD/CDN/LISN 維修
- KT-200SG
KAST
KT-200SG
- HD316
誠臻
電磁兼容
Schloeder GmbH
Band Reject Filter
- SGH-8 AC/DC- MF
- Fully AC/DC DIP compliant
SGH EMC System
AC/DC - MF
AC/DC-DIP
Power Ampilifer
- CDN S4 4xBNC
- CDN S4 XLR4
- CDN S4 DIN5-1
- CDN ISN S8 RJ45
- CDN S9 SUBD
- CDN S9 USB3.0
- CDN S15 VGA
- CDN S19 HDMI
- CDN S24 USB-C
- CDN S25 SUBD
- CDN T8 RJ45
- CDN T4 RJ45
- CDN T4 4A
- CDN T2 16A
Schwarzbeck
Coupling / Decoupling Networks
Pre-Amplifier
各式放大器訂製
低頻放大器
Todaisu
- TAF Calibration Lab
RF-Cable
High low Frequency cable
WP400c
功能特點 (Features):
電場與磁場測量 (Electric & Magnetic field measurement)
各向同性與真實均方根測量 (Isotropic & True RMS measurement)
頻譜分析探頭 (Spectrum analysis probe)
符合國際標準的測量 (Measurements in accordance with International Standards)
100 cm² 感測器 (100 cm² sensor)
主要應用 (Main Applications):
汽車產業 (Automotive)
能源: IEC/EN 62110 (Energy: IEC/EN 62110)
鐵路: EN 50500 (Railway: EN 50500)
焊接: EN 50505 (Welding: EN 50505)
感應加熱(低頻): EN 50519 (Induction heating (LF): EN 50519)
電弧或感應熔煉 (Electric arc or induction smelting)
家用電器: IEC/EN 62233, EN 50366 (Household appliances: IEC/EN 62233, EN 50366)
RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1 (RFID/EAS: EN 50364, EN 50357, IEC/EN 62369-1)
醫療: IEC 60601 (Medical: IEC 60601)
研究/實驗室 (Research/Labs)
電子/電氣設備: IEC/EN 62311 (Electronic/electrical equipment: IEC/EN 62311)
國防(低頻) (Defense (LF))
工作場所評估: EN 50499 (Workplace assessment: EN 50499)
植入式醫療裝置從業人員評估: EN 50527-1 (Assessment of workers bearing AIMDs: EN 50527-1)
人體暴露評估: EN 50413 (Human exposure assessment: EN 50413)
符合 IEC/EN 61786-1 標準,並包含 GB 8702-2014 限值
(In accordance with IEC/EN 61786-1. GB 8702-2014 limit included.)
詳細說明
| Electric Field | Magnetic Field | |
| Sensor type | Isotropic patented electrodes | |
| Frequency range | 1 Hz – 400 kHz | |
| Field Strength Mode | ||
| Measurement range | 1 V/m to 100 kV/m | 50 nT - 30 mT @ 50 Hz 50 nT - 1.5 mT (820 Hz - 40 kHz) · Upper range increases linearly with decreasing frequency below 820 Hz. · Upper range decreases linearly with increasing frequency above 40 kHz. |
| Graphical display | RMS, Axis Values, AVG, MAX, MIN, PEAK, RMS time graph | |
| Peak value | digital realtime | digital realtime |
| Resolution | < 0.4 mV/m above 8 Hz | < 0.1 nT (at 50 Hz) and < 0.05 nT above 100 Hz |
| Noise level | < 1 V/m (10 Hz - 400 kHz) | < 50 nT (10 Hz – 400 kHz) |
| Weigthed Peak Method mode | ||
| Measurement range | 200 % (min) | 200 % (min) |
| Graphical display | PEAK (%), AXIS VALUES (%), AVG (%), MAX (%), MIN (%), RMS (%), Time graph |
|
| Standards/Limits | EU Directive 2013/35/EU, IEEE (except Restricted and Limb), ICNIRP, BGV B11, GB 8702-2014. Easy software update to future modifications and to other limits. |
|
| FFT Mode | ||
| Measurement range | 4 mV/m – 100 kV/m | 0.5 nT - 30 mT @ 50 Hz 0.5 nT - 1.5 mT (820 Hz - 40 kHz) · Upper range increases linearly with decreasing frequency below 820 Hz. · Upper range decreases linearly with increasing frequency above 40 kHz. |
| Graphical display | Frequency analysis, total field and axes | |
| SPAN(Resolution) | 400 Hz (1 Hz) - 4 kHz (10 Hz) - 40 kHz (100 Hz) - 400 kHz (1 kHz) | |
| Noise level | < 4 mV/m | < 0.5 nT |
| FFT | 1024 point FFT | |
| General specifications | ||
| Isotropy | ± 5 % | ± 4 % |
| Typical Uncertainty | 8 % (0.67 dB) | 7.2 % (0.60 dB) |
| Temperature deviation [typ. at 60 Hz] (referred to 25 °C, 50 % relative humidity) |
- 0.005 dB/°C (- 15 °C to 40 °C) | - 0.003 dB/°C (- 15 °C to 25 °C) + 0.003 dB/°C (25 °C to 40 °C) |
| Damage level | > 200 kV/m | > 2000 mT up to 60 Hz Damage level decreases linearly with increasing frequency above 60 Hz |
| Linearity | ± 1 % (typ.) ± 2 % (max.) |
|
| Weight | 220 g | |
| Probe size | 280 mm x 128 mm Ø | |